Data centre cooling & process piping supply

Piping systems for chilled water, condenser loops, CRAH/CRAC units, liquid cooling and high-purity process water — for facilities that cannot go down.

Data centre mechanical hall: large insulated chilled-water pipework with butterfly valves, flow meters and pipe hangers running above rows of white CRAH cooling units

A data centre cooling loop is a process system with a 99.99% availability expectation. We supply the pipe, valves and fittings that go into chilled water plants, CRAH/CRAC branches, CDU piping and liquid cooling manifolds — specified for continuous duty and built for serviceability.

Market

What we supply

Chilled water & condenser loops

Plant room piping, distribution headers and branch connections for the primary cooling system.

  • Chiller plant piping
  • Primary/secondary loops
  • Distribution headers & risers
  • Isolation & balancing valves

Liquid cooling & CDU

Direct-to-chip and immersion cooling distribution — manifolds, quick-disconnects and CDU piping.

  • CDU supply & return piping
  • Rack manifolds & quick-disconnects
  • Coolant distribution components
  • Leak-detection integration

Process & make-up water

Water treatment, make-up, blowdown and high-purity process lines feeding the cooling system.

  • Water treatment plant piping
  • Make-up & blowdown lines
  • High-purity & UPW systems
  • Chemical dosing for treatment

Flow measurement & balance

Metering and instrumentation for cooling efficiency, leak detection and capacity management.

  • Flow meters for loops & branches
  • Temperature & pressure sensors
  • BMS/DCIM integration ready
  • Valve position feedback

Actuation & control

Actuated valves and control elements for automated loop management and fail-safe isolation.

  • Electric & pneumatic actuation
  • Modulating control valves
  • Fail-safe & redundant isolation
  • Automation accessories

Continuity & serviceability

Materials and configurations chosen for maintenance without shutdown.

  • Isolation for service without draining
  • Redundancy-ready layouts
  • Standardised components for spares
  • Fast-turn replacement stock
Data centre piping by system
SystemTypical materialsValvesConsiderations
Chilled water plantCarbon steel, HDPE, PVCButterfly, gate, check, balancingInsulation, thermal movement, freeze protection
CRAH / CRAC branchesSteel, PVC, copperGate, ball, balancingAccess for coil service
Liquid cooling (D2C)Stainless, PP, EPDM-linedBall, control, quick-disconnectCoolant compatibility, leak detection
Immersion coolingStainless, HDPEBall, actuatedFluid compatibility, tank integration
Make-up waterPVC, CPVC, stainlessBall, check, solenoidBackflow prevention, treatment
High-purity / UPWPVDF, PP, stainlessDiaphragm, ballExtractables, dead legs, jointing
System layout

The cooling loop, end to end

Data centre cooling schematic: chillers, pumps, CDU, rack manifold, CRAH/CRAC units and flow instrumentation
Cooling loop from chiller plant through CDU and rack manifold to the CRAH units.
Specification & support

How we support the job

  • Specification review against the mechanical design
  • Materials rated for continuous duty and the fluid chemistry
  • Isolation strategy that allows service without full shutdown
  • Standardised components to simplify spares and maintenance
  • Coordinated delivery to construction and commissioning schedule
  • Documentation for commissioning and closeout packages